120 to 230 Volts Single phase external CT KWh multimeter DIN rail - Pulse output

$ 35.9

Availability: 51 in stock
  • Nominal Voltage Rating: 120 V
  • Operating Frequency: 60 Hz
  • Meter Type: Electronic
  • Display Type: LCD
  • Meter Accuracy: Class 0.1
  • Brand: Beyondtech.com
  • Features: Digital Meters, LCD Backlight
  • Mounting Style: Din Rail Mounting
  • Number of Phases: 1
  • Nominal Current Rating: 45 A
  • Current Type: AC
  • Model: XTM18SA
  • Condition: New

    Description

    Excellent Energy Analysis meter with external CT.
    Read KWh, Voltage, Amps, Frequency, Watts, and more. Configurable communications module.
    1  to 100 Amps Split core CT provided.
    RS485 and pulse connections for AMR systems.
    50 or 60 Hz.
    Split Core CT allows to install the meter away from wires and without having to disconnect or cut wires.
    Din rail standard to keep your meter(s) clean and organized.
    We offer enclosure boxes with Din rail with room for up to 7 sub-meters.
    Some details and specification about this sub meter:
    Meter specifications
    Voltage/current inputs
    Nominal Voltage 230V AC  - It works with Voltages from 120 to 230 V AC
    Voltage range (120-275)V
    Power consumption 0.5W 2VA
    Primary Current(A) 100A
    Second input (mV) 330mV( Primary current=100A) RS485 cable AWG 18
    Terminal flexible 1Xmm2 0-2.5mm2
    General data
    Frequency 50 or 60 Hz
    Accuracy 0.1
    Mechanical
    Material ABS+PC
    Weight 100g
    Environmental
    Operating temperature -25°C +55°C
    Storage temperature -40°C +70°C
    Humanity 75% yearly average,95% on 30 days/year, non-condensing
    Dimension
    Width (mm) 18
    Height (mm) 104.5
    Depth (mm) 88
    Main functions:
    Measuring Function:
    This smart meter can measure import active energy, export active energy, total active energy .
    Import reactive and export reactive energy are available through the RS485 interface
    Electricity parameters measurement:
    Measured parameters from mains:
    Voltage 0.5% of range maximum
    Current 0.5% of nominal FS solid-core sensor and Current 1.0% of nominal FS open-core sensor
    Frequency 0.2% of MID-frequency
    Power factor 1.0% of unity (0.01)
    Active power(W) +/- 1.0% of range maximum
    Reactive power(VAr) +/- 2.0% of range maximum
    Apparent power(VA)  +/- 1.0% of range maximum
    Active energy(lei) Class B EN50470-3
    Reactive energy (kvarh) +/- 2.0% of range maximum
    Display function at power up, the smart meter will initialize and do a self-checking.
    Full screen will last for 3 seconds
    Software version It will last for 3 seconds
    This smart meter has two status: cycle display status and button press display .When pressing the button, it will display total active energy, import active energy, export active energy, voltage, current, active power, frequency, power factor, Modbus id, baud rate , parity Lcd content
    1 Total active energy
    2 Import active energy
    3 Export active energy
    4 Voltage (V)
    5 Current (A)
    6 Active power(W)
    7 Frequency
    8 Power factor (PF)
    9 Modbus id
    10 Baud rate (example: 1200bps
    Instantaneous values
    Communication Functions:
    The Smart meter provides a RS485 port for remote communications. Parameters can be selected from the set mode.
    RS485 communications transfer rates can be selected at 1200bps, 4800bps, 9600bps, or 19200bps, default ls 9600bps
    .
    Panty: None/Even, default is None.
    Modbus address: 001255, default is 001
    The max quantity  of meters on one
    RS485  bus is 64 units, the longest communication distance is 1.2 Km.
    Pulse output function The meter has two pulse output. Both outputs are passive type.
    Pulse output 2 is configurable: constant
    can be selected: 0.001/0.01/0.1/1 imp/kWh or lmp/kvarh, default is limp/kWh.
    Pulse width:60/100/200ms. Pulse output 1is fixed up with total kWh, Constant is 1000imp/kWh
    Programming can be done by holding the key "SET" Pressing the "SET" key for at last 3 secs. starts the programming menu. The LCD will show the prompts.
    The user can also program the meter parameters by sending commands via the RS485 port
    Wiring diagram ports as labeled in the meter:
    1/2 CT In/Out
    3/4 Phase/Neutral
    5/6 SO1 1000 imp/kWh
    7/6 SO2 Configurable
    8/9/10 RS485 Communication contact
    TX/RX(+) Terminal 10
    TX/RX(-) Terminal 9
    G485 (_|_)
    Terminal 6
    Meter instantaneous values displayed.
    Parameters analyzed and kept in memory available to transmit to a computer via RS485 ModBus  with data fields by numbers:
    Main parameters:
    1 Voltage
    2 Frequency
    3 Current
    4 Active power
    5 Apparent power
    6 Reactive power
    7 Power factor
    Total energy accumulator:
    8 Import active energy
    9 Import reactive energy
    10 Reserve (default 0) v
    11 Export active energy
    12 Export reactive energy
    13 Total active energy
    Production data and Identification
    14 Serial number
    15 Manufacture code
    16 Type code
    17 Hardware version
    18 Software version
    19 Reference voltage
    20 Reference current
    21 SO1 Constant
    22 SO2 Output mode:
    0000: kWh
    0001: kvarh
    23  SO2 Output data programmed
    :
    0.001 kWh/imp
    0.01 kWh/imp
    0.1 kWh/imp
    1 kWh/imp (default)
    24  SO2 pulse width
    :
    0000 60ms
    0001 100ms 0002 200ms (default)
    25
    Active energy measurement type
    01 : Total import
    04 : Total export
    05 : Total import+Export
    06 : Total Export-Import
    09 : Total Import-Export
    26  Modbus id
    27  Baud rate Hex(04BO) 1200bps Hex(0960) 2400bps Hex(1 2C0) 4800bps Hex(2580) 9600bps
    Hex(4BOO) 19.2kbps
    28  Network Parity Stop
    0000: None parity /  0001: Even parity
    29  Clear energy