SM852B 3 Phase Sequence Rotation Tester LED Indicator Detector Checker Meter
$ 16.17
- Description
- Size Guide
Description
New phase meter 60V-600V 3 phases AC 2000V/mDescription
Company
New Digital Phase Meter
The meter is based on Second Safety Standard of “Electronic Measure Instrument Safety Require.” Take conveniently, quickly measuring, correctly and safely. The opening phase condition and order can be checked by LED and Buzzer.
Specifications:
MODEL:
SM852B
The
meter is based on Second Safety Standard of “Electronic Measure Instrument Safety Require.” Take conveniently, quickly measuring, correctly and safely. The opening phase condition and order can be checked by LED and Buzzer.
Ⅱ Features
Operational voltage: 60
~
600V (3 phases AC)
Limit support voltage: 2000V/minute (impulse voltage 4000V)
Measuring frequency range: 20Hz
~
400Hz
Time limit for continuous measurement: Less than 60minutes at 200V AC
Less than 4minutes at 600V AC
Meter size: 85
×
64
×
23mm (exclude the measuring lead)
Meter weight: Approximate 200g
Operation manual:
Be sure to read this manual carefully before use it.
Ⅰ
Summarize
The
meter is based on Second Safety Standard of “Electronic Measure Instrument Safety Require.” Take conveniently, quickly measuring, correctly and safely. The opening phase condition and order can be checked by LED and Buzzer.
Ⅱ
Features
Operational voltage: 60
~
600V (3 phases AC)
Limit support voltage: 2000V/minute (impulse voltage 4000V)
Measuring frequency range: 20Hz
~
400Hz
Time limit for continuous measurement: Less than 60minutes at 200V AC
Less than 4minutes at 600V AC
Meter size: 85
×
64
×
23mm (exclude the measuring lead)
Meter weight: Approximate 200g
Attachment: Measuring lead, meter-pen, measure shelf, band, operation manual and hop-pocket.
Ⅲ
Specification
1.
Open phase check by LED: 3 orange LED, show U Phase, V Phase, and W Phase respectively.
2
.
Phase order check through LED: A red LED and a green LED
3. Band: Hitch on wrist to avoid the meter falling.
4. Meter-pen
5. Measuring Lead: red pen is corresponding U Phase (L1, R);
black is corresponding V Phase (L2, S);
blue is corresponding W Phase (L3, T)
Ⅳ
Operation method:
Be connected meter-pen and measuring wire together (Do not use hand directly). Any part of measuring wire is well (When measure in its middle part, shuck off its insulter and prevent get an electric shock. through measuring shelf is inserted in to metal explore nob and screw down, measurement become more convenience for customers). At that time, meter will show the phase and phase order.
Measuring result
Open phase check by LED
Phase order check by LED
Buzzer
Correct phase(CW)
All 3 orange LED are lit
Green LED is lit
Intermittent beep
Reverse phase(CCW)
All 3 orange LED are lit
Red LED is lit
Continuous beep
Open phase(one phase only)
Orange LED for open phase are off
Both green and red LED are off
Ⅴ
Reminds:
1. The meter is high voltage equipment, so check-up before use it. If there is appear follow cases, stop measuring to repairing:
A. Appearance scathe.
B. Extrusion in transit.
C. Store in wet places for long time.
2. Do not open the cover of meter when measuring.
3. Do not use hand to touch the metal of bareness thrum and meter-pen directly.
4. Prevent to get an electric shock when all light off, however, there is loop.
5. It is better to circuit voltage no more than 600V.
6. Time limit for continuous measurement 60 minutes at 200V AC and 4 minutes at 600V AC.
7. Do not use it in open air or other wet places.
8. Do not let it touch water or other liquid or directly to the sun.
9. Only professors can open its cover.
10. Users should take in special train and know well relatively knowledge and operate as this manual.
11. Put this manual under reach.